Galli Ad

Galli Ad is a germanium-68/gallium-68 generator for in vitro radiolabelling of various radiopharmaceuticals with Ga-68 chloride. PI Medical supplies Galli Ad in the Netherlands, together with its accessories.

  • Approved in 29 European countries, in the Netherlands under RVG 120151
  • Works without electricity and without a pump
  • At least 450 elutions or 1 year shelf life

Learn more

    Send

    A Ga-68 generator that works like a technetium generator

    Galli Ad is based on the principles of 99mTc generators. The eluent (sterile 0.1 M HCl) is integrated in the generator. There are no separate HCl bags to connect, and the risk of contamination stays low.

    The generator works by vacuum instead of positive pressure. With a vacuum vial you elute straight into the cold kit vial: elute and label in one step. No syringe pump or peristaltic pump is needed.

    Benefits for your hot lab

    • Minimal equipment: more and more cold kits are coming onto the market, so you can prepare a radiopharmaceutical without a synthesis module. Prefer to prepare it yourself with a synthesis module? That works too: Galli Ad is compatible with all synthesis modules on the market.
    • Low elution volume: 1.1 mL per elution, which speeds up labelling.
    • Simpler quality control: an approved generator combined with an approved cold kit needs less QC equipment and time. Also take a look at our QC equipment, such as the Scan-RAM 2.
    • Elute when it suits you: 91% of the gallium-68 has regrown after 4 hours. You can elute several times a day with a sufficient yield, including for urgent cases or schedule changes.
    • Well shielded: double shielding of lead and tungsten, equivalent to 50 mm of lead.
    • No power needed: the generator is fully manual.

    Applications

    • In vitro radiolabelling of approved cold kits for Ga-68 PET, such as PSMA and somatostatin receptor imaging
    • Preclinical research and the development of new radiopharmaceuticals
    • Training and teaching

    Galli Ad is not intended for direct use in patients.

    Accessories

    • Galli Cap: a module placed on top of the generator. Its control box operates the button remotely, so you can start an elution at any moment while keeping more distance from the source. It also shows the number of elutions. The system is compatible with several synthesis modules.
    • Galli Mov: a rolling support that fits tightly under the generator, so you move it inside the hot cell without lifting.
    • Galli Up: a system for placing two generators on top of each other. This lets you connect two generators while losing as little working space as possible in the LAF cabinet.

     

    Service and sustainability

    The price includes eluent for one year, packaging, a starter kit and transport. When we deliver a new generator, we collect the old one at a time that suits you. About 70% of the non-radioactive parts, such as plastics and shielding, is recycled or reused. Having a problem or a question about using the generator? We are always reachable and you always get a person on the phone who helps you straight away.

    FAQ

    What is a 68Ge/68Ga generator?

    Inside the generator, germanium-68 (half-life 271 days) decays into gallium-68 (half-life 68 minutes). Elution extracts the gallium-68, which you then use to label a cold kit for PET.

    Can I use Galli Ad manually?

    Yes. You elute with a vacuum vial, without a synthesis module or pump. Automated use is also possible: Galli Ad is compatible with all synthesis modules on the market.

    How often can I elute?

    Several times a day, with a sufficient yield. 91% of the gallium-68 has regrown after 4 hours. The generator lasts at least 450 elutions or 1 year.

    Which activity do I need?

    That depends on the number of labellings per day. Galli Ad is available from 0.74 to 1.85 GBq. PI Medical is happy to advise you.

    What happens to the generator after use?

    When we deliver a new generator, we collect the old one at a time that suits you. About 70% of the non-radioactive parts is recycled or reused.

    Can Galli Ad be administered to patients?

    No. The eluate is only intended for in vitro radiolabelling. Refer to the SmPC of the cold kit for administration of the labelled product.